ST 031 "PIRANHA" MULTIFUNCTIONAL COUNTERSURVEILLANCE
INSTRUMENTS
::user`s
manual::software
|
248/1
Certificate of the State Technical Commission, issued
on 14th August 2005
The ST 031 "PIRANHA" multifunctional
countersurveillance instrument is intended for implementation
of arrangements for detection and localization of special
technical means (STM) used for secret acquisition of information,
for revealing of natural and artificially created channels
for leakage of information as well as for monitoring of
information protection quality.
|
Guide the index
at an interesting component |
The instrument consists of the Main Control and Indication
Unit, and a set of Transducers, and is
capable of operating in the following modes:
HF detector/frequency meter, with
the identification of GSM and DECT signals;
conducting line analyser;
infrared detector;
low frequency magnetic field detector;
vibration transducer;
acoustic transducer.
low frequency differential amplifier.
The information is displayed on a liquid crystal screen with adjustable
backlighting.
The instrument is controlled with the aid of a 16-key film keyboard.
Sound output is available via headphones or speaker. The instrument
allows to process the received low frequency signals in either oscilloscopic
mode, or spectrum
analyser mode with a digital representation of data.
Its non-volatile memory can store up to 99 screen images. On the screen, help can be displayed, available in both Russian
and english.
ST 031 can be powered from either 4 type AA batteries, or a power
unit.
ST 031 is a portable unit. For handling and storage a special bag
is used, tailored to house all the components in a convenient way.
ST 031 "Piranha" is protected by utility patent under the
laws of Russian Federation.
Specifications
|
Radio
frequency detector-frequency meter |
| Operating frequency range, MHz |
30-2500 |
| Sensitivity at input, mV |
<1 (30MHz-1000MHz) |
| |
<4 (1000MHz-1800MHz) |
| |
<8 (1800MHz-2000MHz) |
| Dynamic range, dB |
60 |
| Frequency meter sensitivity, mV |
<15 |
| Frequency measurements accuracy, MHz |
+ 0.01 |
Conductive
wire lines scanning analyzer |
| Scanning range, MHz |
0.01-15 |
| Sensitivity for signal/noise ratio 10 dB, mV |
<0.5 |
| Scanning increment, kHz |
5(1) |
| Scanning speed, kHz/s |
50-1500 |
| Band width, kHz |
10 |
| Selectivity as per neighboring channel, dB |
30 |
| Detection modes |
AM, FM |
| Allowable mains voltage, V |
600 |
Infrared
radiation detector |
| Spectral range, nm |
770-1000 |
| Threshold sensitivity, W/Hz1/2 |
10-13 |
| Angle of sight, grad |
30 |
| Band width of detection, MHz |
3 |
Low
frequency magnetic fields detector |
| Frequency range, kHz |
0.3-10 |
| Threshold sensitivity, A/(m*Hz2) |
10-5 |
Low frequency
differential amplifier |
| Gain, dB |
22+1 |
| Input voltage noise, mcV |
<2 |
| Dynamic range, dB |
>70 |
| Input impedance, kOhm |
>200 |
| CMRR, dB |
75 |
| Operating frequency range, Hz |
200-8000 |
| Maximum input voltage, V |
<70 |
Vibro-acoustic
converter |
| Frequency range, kHz |
0.3-6 |
| Sensitivity, V*s2/m |
1 |
| Intrinsic noise within the band of 0.3-3 kHz, uV |
50 |
Acoustic
converter |
| Frequency range, kHz |
0.3-8 |
| Sensitivity, mV/Pa |
>5 |
Oscilloscope
and spectrum analyzer |
| Band width, kHz |
22 |
| Sensitivity at the input, mV |
<10 |
| Metering error, % (of the upper limit) |
1 |
| Oscillogram output speed, s |
0.2 |
| Spectrogram output speed, s |
0.3 |
Power |
| Power supply (DC), V |
6(4 batteries, AA type)/220 |
| Maximum consumed current, mA |
300 |
| Consumed current in operating mode, mA |
150 |
Dimensions
and weight |
| The principal control, processing and indication unit:
overall dimensions, mm |
180х97х47 |
| The principal control, processing and indication unit:
weight, kg |
0.8 |
| Complete set: overall dimensions, mm |
350х310х160 |
| Complete set: weight, kg |
not exceeding 5 |
|
|
| The complete set of the instrument
includes the following components: |
| Name |
pieces |
| 1. The main control processing and indication unit. |
1 |
| 2. Radio frequency antenna. |
1 |
| 3. Adapter for conductive wire lines' scanning analyzer. |
1 |
| 4. Conductive wire lines' differential adapter *. |
1 |
| 5. Magnetic sensor. |
1 |
| 6. Infrared sensor. |
1 |
| 7. Vibro-acoustic sensor. |
1 |
| 7a. Acoustic sensor. |
1 |
| 8. Telescopic antenna. |
1 |
| 9. "Needle" type extensions. |
2 |
| 10. "220" type extensions. |
2 |
| 11. "Alligator" clip type extensions. |
2 |
| 12. Headphones. |
1 |
| 13. Connecting cable for magnetic and infrared sensors. |
1 |
| 14. Telescopic antenna adapter. |
1 |
| 15. Shoulder belt for the main unit, with a pocket for sensors. |
1 |
| 16. Main unit support. |
1 |
| 17. Power supply unit. |
1 |
| 18. AA type batteries. |
4 |
| 19. "TEST" monitoring device.* |
1 |
| 20. Technical Description and Operating Manual. |
1 |
- * Optional item to be ordered separately.
|