ST 031P "PIRANHA" MULTIFUNCTIONAL COUNTERSURVEILLANCE
INSTRUMENTS
::user`s
manual::software
|
ST 031P = ST
031 'PIRANHA'+ DIGITAL INTERFASE
that provides the added features of:
operation with an IBM PC-compatible computer
control of the scanning receiver
SOFTWARE UPGRADES
Control of the scanning receiver (AOR8000, 8200, 5000).
The scanning receiver can be controlled while the instrument
operates in the HF detector/frequency meter mode, and conductive
line scanning analyser mode. The action is based on tuning the
receiving frequency of the scanning receiver, to match the frequency
of the signal received. This may be performed automatically, when
the frequency is registered by the HF detector, or manually by
the user. This feature allows prompt checking of the detected
signal, aided with the capabilities of a scanning receiver. |
Guide the index
at an interesting component |
Operation with an IBM PC or PC-compatible computer
For operation with an IBM PC or PC-compatible computer, a program
specifically developed for the purpose is used, that allows
the transfer of information from ST 031P's display on to the computer
monitor
the creation of a database of graphic and audio files, that are
being generated in the process of operation with ST 031P in real time,
or are retrieved from ST 031P's non-volatile memory.
In mode of HF detector/ frequency meter identification of Bluetooth
and Wi - Fi signal is added.
For software upgrades (new versions, additional features), connect
ST 031 via Serial Port to your PC, and visit the manufacturer's site;
the instrument will be reprogrammed automatically.
Specifications
|
Radio frequency
detector-frequency meter |
| Operating frequency range, MHz |
30-2500 |
| Sensitivity at input, mV |
<1 (30MHz-1000MHz) |
| |
<4 (1000MHz-1800MHz) |
| |
<8 (1800MHz-2000MHz) |
| Dynamic range, dB |
60 |
| Frequency meter sensitivity, mV |
<15 |
| Frequency measurements accuracy, MHz |
+ 0.01 |
Conductive wire
lines scanning analyzer |
| Scanning range, MHz |
0.01-15 |
| Sensitivity for signal/noise ratio 10 dB, mV |
<0.5 |
| Scanning increment, kHz |
5(1) |
| Scanning speed, kHz/s |
50-1500 |
| Band width, kHz |
10 |
| Selectivity as per neighboring channel, dB |
30 |
| Detection modes |
AM, FM |
| Allowable mains voltage, V |
600 |
Infrared radiation
detector |
| Spectral range, nm |
770-1000 |
| Threshold sensitivity, W/Hz1/2 |
10-13 |
| Angle of sight, grad |
30 |
| Band width of detection, MHz |
3 |
Low frequency
magnetic fields detector |
| Frequency range, kHz |
0.3-10 |
| Threshold sensitivity, A/(m*Hz2) |
10-5 |
Low frequency differential
amplifier |
| Gain, dB |
22+1 |
| Input voltage noise, mcV |
<2 |
| Dynamic range, dB |
>70 |
| Input impedance, kOhm |
>200 |
| CMRR, dB |
75 |
| Operating frequency range, Hz |
200-8000 |
| Maximum input voltage, V |
<70 |
Vibro-acoustic
converter |
| Frequency range, kHz |
0.3-6 |
| Sensitivity, V*s2/m |
1 |
| Intrinsic noise within the band of 0.3-3 kHz, uV |
50 |
Acoustic converter |
| Frequency range, kHz |
0.3-8 |
| Sensitivity, mV/Pa |
>5 |
Oscilloscope
and spectrum analyzer |
| Band width, kHz |
22 |
| Sensitivity at the input, mV |
<10 |
| Metering error, % (of the upper limit) |
1 |
| Oscillogram output speed, s |
0.2 |
| Spectrogram output speed, s |
0.3 |
Power |
| Power supply (DC), V |
6(4 batteries, AA type)/220 |
| Maximum consumed current, mA |
300 |
| Consumed current in operating mode, mA |
150 |
Dimensions and
weight |
| The principal control, processing and indication unit: overall
dimensions, mm |
180х97х47 |
| The principal control, processing and indication unit: weight,
kg |
0.8 |
| Complete set: overall dimensions, mm |
350х310х160 |
| Complete set: weight, kg |
not exceeding 5 |
|
|
| The complete set of the instrument
includes the following components: |
| Name |
pieces |
| 1. The main control processing and indication unit. |
1 |
| 2. Radio frequency antenna. |
1 |
| 3. Adapter for conductive wire lines' scanning analyzer. |
1 |
| 4. Conductive wire lines' differential adapter .* |
1 |
| 5. Magnetic sensor. |
1 |
| 6. Infrared sensor. |
1 |
| 7. Vibro-acoustic sensor. |
1 |
| 7a. Acoustic sensor. |
1 |
| 8. Telescopic antenna. |
1 |
| 9. "Needle" type extensions. |
2 |
| 10. "220" type extensions. |
2 |
| 11. "Alligator" clip type extensions. |
2 |
| 12. Headphones. |
1 |
| 13. Connecting cable for magnetic and infrared sensors. |
1 |
| 14. Telescopic antenna adapter. |
1 |
| 15. Installation disc with software. |
1 |
| 16. Cable for connection to IBM PC and scanning receiver. |
1 |
| 17. Cable for recording of audio information. |
1 |
| 18. Shoulder belt for the main unit, with a pocket for sensors. |
1 |
| 19. Main unit support. |
1 |
| 20. Power supply unit. |
1 |
| 21. AA type batteries. |
4 |
| 22. "TEST" monitoring device.* |
1 |
| 23. Technical Description and Operating Manual. |
1 |
* Optional item to be ordered separately.
|