ST 032 Multifunctional Detection Instrument
::user`s
manual ::software
|
The ST 032 Multifunctional Detection Instrument
is used to detect and locate various appliances used for furtive
acquisition of information (hereinafter called 'Special Technical
Means', or 'STM'), to reveal natural and artificial channels of
information leakage, and to monitor the level of information security.
|
Guide the index at an
interesting component |
The instrument consists of the Main Control and Indication
Unit, and a set of Transducers, and is capable of operating in the following
modes:
-
- The information is displayed on a liquid crystal screen.
Sound output is available via headphones or speaker.
ST 032 can be powered from 1 type AA battery, or a power unit. ST
032 is a portable unit. For handling and storage a special bag is
used, tailored to house all the components in a convenient way.
-
-
Specifications
|
Radio frequency
detector-frequency meter |
| Operating frequency range, MHz |
30-2500 |
| Sensitivity at input, mV |
<1
(30MHz-1000MHz) |
| |
<4
(1000MHz-1800MHz) |
| Dynamic range, dB |
63 |
| Frequency meter sensitivity, mV |
<15 |
| Frequency measurements accuracy, MHz |
+ 0.01 |
Conductive
wire lines scanning analyzer |
| Scanning range, MHz |
0.05-9 |
| Sensitivity for signal/noise ratio 10 dB, mV |
<1 |
| Band width, kHz |
10 |
| Detection modes |
AM, FM |
| Allowable mains voltage, V |
600 |
Infrared radiation
detector |
| Spectral range, nm |
770-1000 |
| Band width of detection, MHz |
0.3-300 |
| Threshold sensitivity, W/Hz1/2 |
10-13 |
Low frequency
magnetic fields detector |
| Frequency range, kHz |
0.5-300 |
| Threshold sensitivity, T/Hz1/2 |
10-11 |
Vibro-acoustic
converter |
| Frequency range, kHz |
0.3-6 |
| Sensitivity, V*s2/m |
1 |
Acoustic converter |
| Frequency range, kHz |
0.3-8 |
| Sensitivity, mV/Pa |
>5 |
Low frequency
differential amplifier |
| Normalized noise voltage at the input, uV |
<2 |
| Dynamic range, dB |
60 |
| Input impedance, kOhm |
200 |
| Common-mode interference damping factor, dB |
>60 |
| Frequency range, kHz |
0.2-15 |
| Maximum allowable input voltage, V |
70 |
Power |
| Power supply (DC), V |
1.5
(1 battery, AA type)/220 |
| Maximum consumed current, mA |
<200 |
| Consumed current in operating mode, mA |
<100 |
Dimensions
and weight |
| The principal control, processing and indication unit: overall
dimensions, mm |
157х62х28 |
| The principal control, processing and indication unit: weight,
kg |
0.25 |
| Complete set: overall dimensions, mm |
|
| Complete set: weight, kg |
1 |
|
|
| The complete set of the instrument
includes the following components: |
| Name |
pieces |
| 1. Principal Control, Processing, and Indication Unit. |
1 |
| 2. Adapter for the Conducting Line Scanning Analyser |
1 |
| 3. Cable for the LF Differential Amplifier. |
1 |
| 4. Acoustic Vibration Sensor*. |
1 |
| 5. Acoustic Sensor*. |
1 |
| 6. Needle Type Extensions (2pcs.). |
2 |
| 7. "220" type extensions. |
2 |
| 8. "Alligator" clip type extensions. |
2 |
| 9. Headphones. |
1 |
| 10. Cable for connection to IBM PC and scanning receiver. |
1 |
| 11. Power Supply Unit. |
1 |
| 12. АА Battery. |
1 |
| 13. Technical Description and Operating Manual. |
1 |
| 14. Packaging Bag. |
1 |
* Optional item to be ordered separately.
|